The LocationEmissionsProcess component is used to identify the process for which emissions are being reported. This component has the shared complex type of Process.
Multiple processes/activities for a nonpoint location. Although not required, you are encouraged to report all SCCs for a given nonpoint location in a single submission. You are also encouraged to report all nonpoint locations for your jurisdiction in a single submittal.
List of acceptable SCCs. EPA has defined a list of SCCs which will be acceptable for nonpoint emissions. Consult the list of nonpoint SCCs available in the Gateway. If you would like to request that an SCC be added to the list of acceptable activities/processes for nonpoint emissions reporting, submit a support request through the EIS Gateway
Completeness. There is no single list of processes and activities that would be applicable to a specific location that can be used as a definitive check of submission completeness.
Alternative SCCs. There are some emission sectors, such as architectural coatings, for which you may submit either general codes (all solvent types), or more specific codes (water-based, solvent-based). You must submit using one or the other approach, not both.
If you submit emissions data using the general SCC in one submission and then use detailed SCCs in a subsequent submission for the same Counties, the EIS will delete the general SCC and all related emissions and activity data, and accept the detailed SCCs and their emissions. Similarly, EIS will replace the detailed SCCs and related emissions if general SCCs and emissions are received at a later time.
EPA Source Classification Code that identifies an emissions process.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
187 | SCC Present for Process | A source classification code is required when reporting the emissions process component. The component and all dependent data will not be stored if there are missing required data. | Present | Critical |
90 | SCC Valid for all future years | SCC must exist in code list and have a null Last Inventory Year. | Code | Critical |
Defines the type of emissions produced by Onroad and Nonroad sources. Used for Mobile sources only. Examples include exhaust, evaporative and tire wear.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
614 | Emissions Type Code Valid | Must match value in code list. | Code | Critical |
613 | Emissions Type Code Present | Required when reporting the process component for nonroad. The component and all dependent data will not be stored if there are missing required data. | Present | Critical |
2326 | Not an acceptable Pollutant and Emissions Type combination. | Pollutants and Emission Type Codes are checked against a predefined combination list and this validation failed for combination. | Present | Critical |
Any comments regarding the emissions process.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
270 | Process Comment Data Type | Maximum allowable width of 400 characters. Longer submissions will be truncated. | Format | Warning |
Number | Name | Description | Type | Severity |
---|
Number | Name | Description | Type | Severity |
---|
The source of the supplemental parameter data used.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|
Number | Name | Description | Type | Severity |
---|
SLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
2326 | Not an acceptable Pollutant and Emissions Type combination | Pollutants and Emission Type Codes are checked against a predefined combination list and this validation failed for combination. | Present | Critical |
1789 | SCC in Correct Data Category | The SCC must match the Data Category provided in the Exchange Header. | Conditional | Critical |
2322 | Shape Type Not Matching Allowed SCC | When submitting CMV/Rail Emissions the Shape Type and SCC must match accepted value combinations. The component and all dependent data will not be stored if there is a mismatch. | Present | Critical |