Process Control Approach Component


The ControlApproach component is the parent component of the Control group. It consists of the approach's overall characteristics including capture efficiency, effectiveness (i.e., percent of time operating as designed), and penetration (collective impact of all regulations).

If a control approach is being used for a given location, it must be reported. Therefore, for each combination of location, SCC, and reporting period, you should submit zero or one ControlApproach record.

ControlApproachDescription


Description

Complex data type which identifies the overall control system or approach, including capture effectiveness, where applied at an emissions unit activity or process to reduce the amount of pollutants released into the environment.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
239 Control Approach Description Data Type Maximum allowable width of 200 characters. Longer submissions will be truncated. Format Warning

PercentControlApproachCaptureEfficiency


Description

An estimate of that portion of an affected emission stream that is collected and routed to the control measures when the capture or collection system is operating as designed, reported as a percent.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
115 Percent Control Approach Capture Efficiency Range Should be greater than or equal to 5, and less than or equal to 100.0. Range Critical
240 Percent Control Approach Capture Efficiency Data Type This element must be reported as a decimal, reported with a maximum precision of 5.1. Format Critical

PercentControlApproachEffectiveness


Description

An estimate of the portion of the reporting period's activity for which the overall control system or approach (including both capture and control measures) were operating as designed (regardless of whether the control measure is due to rule or voluntary).

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
116 Percent Control Approach Effectiveness Range Should be greater than or equal to 1, and less than or equal to 100.0. Range Critical
241 Percent Control Approach Effectiveness Data Type This element must be reported as a decimal, reported with a maximum precision of 5.1. Format Critical

PercentControlApproachPenetration


Description

An estimate of the percent value of the nonpoint activity throughput that is affected by a rule or voluntary approach for the given location. (Nonpoint only.)

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
549 Percent Control Measure Penetration Range Must be greater or equal to than 1.1 and less than or equal to 100.0. Range Critical
534 Percent Control Measure Penetration Data Type This element must be reported as a decimal, reported with a maximum precision of 5.1. Format Critical

FirstInventoryYear


Description

The inventory year for which the controls were implemented.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
117 Control Approach First Inventory Year Range The year reported should be between 1900 to 2050. Range Critical
119 Control Approach First and Last Inventory Year Comparison First inventory year must be a value prior or equal to last inventory year. Range Critical
242 First Inventory Year for Control Approach Data Type This element must be reported as an integer. Format Critical

LastInventoryYear


Description

The last inventory year for which the controls were implemented.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
118 Control Approach Last Inventory Year Range The year reported should be between 1900 to 2050. Range Critical
243 Last Inventory Year for Control Approach Data Type This element must be reported as an integer. Format Critical

ControlApproachComment


Description

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
244 Control Approach Comment Data Type Maximum allowable width of 400 characters. Longer submissions will be truncated. Format Warning

ControlMeasure


Description

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity

ControlPollutant


Description

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity

Process Control Approach

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
120 Control Approach Minimum Measures Present Each Control Approach component must be associated with at least one control measure. The component and all dependent data will not be stored if there are missing required data. Present Critical
121 Control Approach Minimum Pollutants Present Each Control Approach component must be associated with at least one control pollutant. The component and all dependent data will not be stored if there are missing required data. Present Critical
224 Control Approach Reported at Multiple Levels If a control approach is reported, it must be reported at either the emissions unit or the emissions process but not both for the same emissions unit. Cardinality Critical