The Emissions component is used to report emissions values for a process, reporting period, and pollutant.
Calculation methods. EPA is requiring the reporting of the emissions calculation method and has defined the list of acceptable emissions calculation method codes. To request that a code be added to the list, submit a support request through the EIS Gateway.
Units of measure for emissions. You are required to identify the unit of measure for reporting all emissions to the EIS. The EIS will accept emissions reported in other recognizable units of measure, but will convert them to the preferred unit of measure for storage in EIS.
Correcting or deleting a single pollutant. As described earlier, there is no batch method to resubmit, correct, or delete emissions associated with a single pollutant except by resubmitting the complete Point Submittal Data Block. An individual pollutant record can, however, be modified through the EIS Gateway
Code identifying the pollutant for which emissions are reported.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
471 | Pollutant Code Present for Emissions | Required when reporting the Emissions component. The component and all dependent data will not be stored if there are missing required data. | Present | Critical |
470 | Active Pollutant Code Valid | Must match active value in code list. | Code | Critical |
832 | PM Primaries Emissions Comparison | PM2.5 Primary can not exceed PM10 Primary | Conditional | Critical |
835 | PM Filterables Emissions Comparison | PM2.5 Filterable can not exceed PM10 Filterable | Conditional | Critical |
Total calculated or estimated amount of the pollutant.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
473 | Total Emissions Present | Required when reporting the Emissions component. The component and all dependent data will not be stored if there are missing required data. | Present | Critical |
474 | Total Emissions Critical Range | Must be inside the critical outlier range when the reporting period type code is "A" (Annual). | Range | Warning |
569 | Total Emissions Data Type | This element must be reported as a float, reported with a maximum of 6 significant figures. | Format | Critical |
2052 | Emissions Greater than or Equal to Zero | The total emissions values for emissions must be greater than or equal to 0. | Range | Critical |
2313 | Total Acceptable Emissions Range | Must be within acceptable emissions range. | Range | Warning |
Unit of measure for reported emissions.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
479 | Emissions Unit of Measure Code Present | Required when reporting the Emissions component. The component and all dependent data will not be stored if there are missing required data. | Code | Critical |
476 | Emissions Unit of Measure Code Valid | Must match value in code list. | Present | Critical |
The emission factor used for the emissions value if a calculated value was provided.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
480 | Emission Factor Data Type | This element must be reported as a float, reported with a maximum of 4 significant figures. | Format | Critical |
611 | Emission Factor Range | Must be greater than zero. | Range | Critical |
The numerator for the unit of measure of the reported emission factor.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
482 | Emission Factor Numerator Unit of Measure Code Valid | Must match value in code list. | Code | Critical |
570 | Emission Factor Numerator Unit of Measure Conditionally Required | If the emission factor is reported, then the emission factor numerator unit of measure is required. | Conditional | Critical |
The denominator for the unit of measure of the reported emission factor.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
483 | Emission Factor Denominator Unit of Measure Code Valid | Must match value in code list. | Code | Critical |
571 | Emission Factor Denominator Unit of Measure Conditionally Required | If the emission factor is reported, then the emission factor denominator unit of measure is required. | Conditional | Critical |
Explanation for emission factor.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
484 | Emission Factor Text Data Type | Maximum allowable width of 100 characters. Longer submissions will be truncated. | Format | Warning |
Code that defines the method used to calculate emissions.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
486 | Emission Calculation Method Code Present | Required when reporting the Emissions component. The component and all dependent data will not be stored if there are missing required data. | Present | Critical |
Any comments regarding the emissions, method of calculation, or emission factor.
User Role AccessibilitySLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
487 | Emissions Comment Data Type | Maximum allowable width of 400 characters. Longer submissions will be truncated. | Format | Warning |
SLT, Inventory Developer
Number | Name | Description | Type | Severity |
---|---|---|---|---|
1930 | Pollutant Not Repeated Within Process | When reporting emissions, a pollutant may not reported multiple times under a single reporting period. | Cardinality | Critical |
2357 | PM10 Primary and Filterable Emissions Comparison | PM10 Filterable can not exceed PM10 Primary | Conditional | Critical |
2358 | PM2.5 Primary and Filterable Emissions Comparison | PM2.5 Filterable can not exceed PM2.5 Primary | Conditional | Critical |
2359 | PM10 Primary and PM Condensable Emissions Comparison | PM Condensable can not exceed PM10 Primary | Conditional | Critical |
2360 | PM2.5 Primary and PM Condensable Emissions Comparison | If PM Condensable and PM2.5 Primary are both reported pollutants, then PM Condensable should not exceed PM2.5 Primary for the same reporting period. | Conditional | Critical |
2361 | PM10-PRI must be sum of its pieces | PM10-FIL + PM-CON must equal PM10-PRI | Conditional | Warning |
2362 | PM25-PRI must be sum of its pieces | PM25-FIL + PM-CON must equal PM25-PRI | Conditional | Warning |
832 | PM Primaries Emissions Comparison | PM2.5 Primary can not exceed PM10 Primary | Conditional | Critical |
835 | PM Filterables Emissions Comparison | PM2.5 Filterable can not exceed PM10 Filterable | Conditional | Critical |