Reporting Period Emissions Component


The Emissions component is used to report emissions values for a process, reporting period, and pollutant.

Calculation methods. EPA is requiring the reporting of the emissions calculation method and has defined the list of acceptable emissions calculation method codes. To request that a code be added to the list, submit a support request through the EIS Gateway.

Units of measure for emissions. You are required to identify the unit of measure for reporting all emissions to the EIS. The EIS will accept emissions reported in other recognizable units of measure, but will convert them to the preferred unit of measure for storage in EIS.

Correcting or deleting a single pollutant. As described earlier, there is no batch method to resubmit, correct, or delete emissions associated with a single pollutant except by resubmitting the complete Point Submittal Data Block. An individual pollutant record can, however, be modified through the EIS Gateway

PollutantCode


Description

Code identifying the pollutant for which emissions are reported.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
471 Pollutant Code Present for Emissions Required when reporting the Emissions component. The component and all dependent data will not be stored if there are missing required data. Present Critical
470 Active Pollutant Code Valid Must match active value in code list. Code Critical
832 PM Primaries Emissions Comparison PM2.5 Primary can not exceed PM10 Primary Conditional Critical
835 PM Filterables Emissions Comparison PM2.5 Filterable can not exceed PM10 Filterable Conditional Critical

TotalEmissions


Description

Total calculated or estimated amount of the pollutant.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
473 Total Emissions Present Required when reporting the Emissions component. The component and all dependent data will not be stored if there are missing required data. Present Critical
474 Total Emissions Critical Range Must be inside the critical outlier range when the reporting period type code is "A" (Annual). Range Warning
569 Total Emissions Data Type This element must be reported as a float, reported with a maximum of 6 significant figures. Format Critical
2052 Emissions Greater than or Equal to Zero The total emissions values for emissions must be greater than or equal to 0. Range Critical
2313 Total Acceptable Emissions Range Must be within acceptable emissions range. Range Warning

EmissionsUnitofMeasureCode


Description

Unit of measure for reported emissions.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
479 Emissions Unit of Measure Code Present Required when reporting the Emissions component. The component and all dependent data will not be stored if there are missing required data. Code Critical
476 Emissions Unit of Measure Code Valid Must match value in code list. Present Critical

EmissionFactor


Description

The emission factor used for the emissions value if a calculated value was provided.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
480 Emission Factor Data Type This element must be reported as a float, reported with a maximum of 4 significant figures. Format Critical
611 Emission Factor Range Must be greater than zero. Range Critical

EmissionFactorNumeratorUnitofMeasureCode


Description

The numerator for the unit of measure of the reported emission factor.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
482 Emission Factor Numerator Unit of Measure Code Valid Must match value in code list. Code Critical
570 Emission Factor Numerator Unit of Measure Conditionally Required If the emission factor is reported, then the emission factor numerator unit of measure is required. Conditional Critical

EmissionFactorDenominatorUnitofMeasureCode


Description

The denominator for the unit of measure of the reported emission factor.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
483 Emission Factor Denominator Unit of Measure Code Valid Must match value in code list. Code Critical
571 Emission Factor Denominator Unit of Measure Conditionally Required If the emission factor is reported, then the emission factor denominator unit of measure is required. Conditional Critical

EmissionFactorText


Description

Explanation for emission factor.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
484 Emission Factor Text Data Type Maximum allowable width of 100 characters. Longer submissions will be truncated. Format Warning

EmissionCalculationMethodCode


Description

Code that defines the method used to calculate emissions.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
486 Emission Calculation Method Code Present Required when reporting the Emissions component. The component and all dependent data will not be stored if there are missing required data. Present Critical

EmissionsComment


Description

Any comments regarding the emissions, method of calculation, or emission factor.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
487 Emissions Comment Data Type Maximum allowable width of 400 characters. Longer submissions will be truncated. Format Warning

ReportingPeriodEmissions

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
1930 Pollutant Not Repeated Within Process When reporting emissions, a pollutant may not reported multiple times under a single reporting period. Cardinality Critical
2357 PM10 Primary and Filterable Emissions Comparison PM10 Filterable can not exceed PM10 Primary Conditional Critical
2358 PM2.5 Primary and Filterable Emissions Comparison PM2.5 Filterable can not exceed PM2.5 Primary Conditional Critical
2359 PM10 Primary and PM Condensable Emissions Comparison PM Condensable can not exceed PM10 Primary Conditional Critical
2360 PM2.5 Primary and PM Condensable Emissions Comparison If PM Condensable and PM2.5 Primary are both reported pollutants, then PM Condensable should not exceed PM2.5 Primary for the same reporting period. Conditional Critical
2361 PM10-PRI must be sum of its pieces PM10-FIL + PM-CON must equal PM10-PRI Conditional Warning
2362 PM25-PRI must be sum of its pieces PM25-FIL + PM-CON must equal PM25-PRI Conditional Warning
832 PM Primaries Emissions Comparison PM2.5 Primary can not exceed PM10 Primary Conditional Critical
835 PM Filterables Emissions Comparison PM2.5 Filterable can not exceed PM10 Filterable Conditional Critical