Every facility site must have at least one emissions unit. An emissions unit is any significant activity, stationary article, process equipment, machine, or other device that emits air pollutants.

For the EIS, an emissions unit may represent the traditional unit concept, such as a boiler, flare, or turbine. However, a "unit" may also represent a group of units, if they are all identical in their characteristics and they are permitted or report emissions collectively. Finally, a "unit" may be defined to represent a source of fugitive emissions at a facility, such as those produced at a landfill or from all unpaved roads within the facility boundaries.

Use the EmissionsUnit component to report information about emissions units at a facility site. A facility site may have one or more emissions units, and each emissions unit must have at least one emissions process. The data elements for emissions units identify a specific unit, its physical attributes, and its operating status. Other related components provide further information about the unit's processes, regulations, and control approaches.

Impact of incomplete information or critical errors. If there are critical errors relating to data elements that require reporting codes, these data elements will not be stored, but all other data in the record will be accepted. If a reporting code for unit of measure is not valid, the data value for which it supports will also not be accepted. If the check that looks for required emissions unit identifiers fails, no data for that unit will be accepted.

UnitDescription


Description

Name of the organization.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
276 Unit Description Data Type Maximum allowable width of 100 characters. Longer submissions will be truncated. Format Warning

UnitTypeCode


Description

Code that identifies the type of emissions unit activity.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
67 Unit Type Code Present The unit type code is required when reporting the EmissionsUnit component. The component and all dependent data will not be stored if there are missing required data. Present Critical
68 Unit Type Code Valid Must match value in code list. Code Critical

UnitDesignCapacity


Description

The measure of the size of the unit based on the maximum continuous throughput capacity of the unit.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
69 Design Capacity Conditionally Present The design capacity should be reported for unit type codes: 100, 120, 140, 160, and 180. Present Warning
199 Design Capacity Range Should be between 0.01 to 100,000,000; inclusive. Range Critical
277 Design Capacity Data Type This element must be reported as a float. Format Critical

UnitDesignCapacityUnitofMeasureCode


Description

Unit of measure for the design capacity of the emissions unit.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
70 Design Capacity Unit of Measure Present Design capacity and design capacity unit of measure must both be reported for either to be accepted. Present Critical
71 Design Capacity Unit of Measure Code Valid Must match value in code list. Code Critical

UnitStatusCode


Description

Code that identifies the operating status of the emissions unit.

User Role Accessibility

SLT, Inventory Developer
[State/Local/Tribe Only] *

Checks
Number Name Description Type Severity
185 Unit Status Code Present The unit status code is required when reporting the EmissionsUnit component. The component and all dependent data will not be stored if there are missing required data. Present Critical
72 Emissions Unit Status Code Valid Must match value in code list. Code Critical
74 Emissions Unit Status Code and Year If emissions unit status code is not "Operating" (OP), the emissions unit status code year must be reported. Conditional Critical
1031 Operating Status Dependency for Emissions Units An emissions unit operating status may not be changed if the facility site operating status is "Temporarily Shutdown" (TS) or "Permanently Shutdown" (PS). Conditional Critical
1449 Unit Operating Status at Shutdown Facility An emissions unit at a facility site with operating status of "Temporarily Shutdown" (TS) or "Permanently Shutdown" (PS) may not have a status of "Operating" (OP). Conditional Critical
1975* Emissions Reported Only for Operating Units Emissions submitted by state, local, or tribal agencies are not accepted for a unit that has a unit status code other than "Operating" (OP), except where facility source type is "Landfill" or if the unit operating status code year is greater than the current inventory cycle year. Conditional Critical

UnitStatusCodeYear


Description

Code that identifies the operating status of the emissions unit.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
73 Emissions Unit Status Code Year in Range The year reported should be between 1900 to 2050. Range Critical
74 Emissions Unit Status Code and Year If emissions unit status code is not "Operating" (OP), the emissions unit status code year must be reported. Conditional Critical
278 Unit Status Code Year Data Type This element must be reported as an integer. Format Critical
2551 Unit Operating Status Year With Emissions The operating status year for statuses other than ""OP"" must be greater than the latest year of emissions submitted to that unit, except for landfills. Conditional Critical

UnitOperationDate


Description

The date on which unit activity became operational.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
75 Emissions Unit Operation Date Range The operation date should be between 01/01/1900 to 12/31/2050. Range Critical
83 Effective Date Range for Unit Identification The effective date range must be between 01/01/1900 to 12/31/2050. Range Critical
85 End Date Range for Unit Identification The end date must be between 01/01/1900 to 12/31/2050. Range Critical
279 Unit Operation Date Data Type Date in the format of YYYY-MM-DD. Format Critical

PermitStatusCode


Description

The operation status of a permit that applies to an emissions unit.

User Role Accessibility

Inventory Developer

Checks
Number Name Description Type Severity
2345 Unit Permit Status Code and End Year If Unit Permit Status Code is not "operating" (O) an end year must be provided. Conditional Critical

PermitStatusBeginYear


Description

The beginning year of a permit that applies to an emissions unit.

User Role Accessibility

Inventory Developer

Checks
Number Name Description Type Severity
2341 Emissions Unit Permit Status Begin Year Range The year reported should be between 1900 to 2050. Range Critical
2343 Unit Permit Status Begin Year Data Type This element must be reported as an integer. Format Critical

PermitStatusEndYear


Description

The ending year of a permit that applies to an emissions unit.

User Role Accessibility

Inventory Developer

Checks
Number Name Description Type Severity
2342 Emissions Unit Permit Status End Year Range The year reported should be between 1900 to 2050. Range Critical
2344 Unit Permit Status End Year Data Type This element must be reported as an integer. Format Critical
2345 Unit Permit Status Code and End Year If Unit Permit Status Code is not "operating" (O) an end year must be provided. Conditional Critical

UnitComment


Description

Any comments regarding the emissions unit activity.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
280 Emissions Unit Comment Data Type Maximum allowable width of 400 characters. Longer submissions will be truncated. Format Warning

UnitIsReadOnly


Description

An indicator defining that no data for the unit may be changed.

User Role Accessibility

Inventory Developer

Checks
Number Name Description Type Severity
2353 Emissions Unit Protected If the data in the EIS for emissions unit is protected, the data will not be stored. A request to unprotect the data can be made through the Gateway Conditional Critical

DesignCapacityIsReadOnly


Description

Indicator defining that the design capacity information for a unit cannot be changed.

User Role Accessibility

Inventory Developer

Checks
Number Name Description Type Severity
1249 Emissions Unit Design Capacity Protected If the data in the EIS for emissions unit design capacity and design capacity unit of measure are protected, the data will not be stored. A request to unprotect the data can be made through the Gateway. Conditional Critical

UnitIdentificationComplex data type

User Role Accessibility
Checks
Number Name Description Type Severity

UnitRegulationComplex data type

User Role Accessibility
Checks
Number Name Description Type Severity
Checks