Unit Identification Component


This component is used to report unit identifiers to the EIS. These include both EIS and Agency identifiers, which are indicated by the Program System Code provided.

If you intend to establish a new emissions unit identifier or indicate that an emissions unit identifier will no longer be used, you may either (1) submit this information using the UnitIdentification components in your batch report; or (2) update the identifier(s) using the EIS Gateway. For example, if you assign a new Agency unit identifier to a unit, report the new identifier in the UnitIdentification component and the previous (replaced) Agency identifier in the UnitIdentification component with the end date provided.

Impact of incomplete information or critical errors. If there are critical errors relating to the dates reported, the dates will not be stored; all other data in the record will be accepted.

Identifier


Description

Complex data type to define identifiers by which an entity is known or has been known.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
167 Identifier Present for Unit Identification The identifier is required when reporting the unit identification component. The component and all dependent data will not be stored if there are missing required data. Present Critical
271 Identifier Data Type for Unit Identification Maximum allowable width of 20 characters. Longer submissions will be rejected. Format Critical
66 EIS Emissions Unit Identifier Exists Must match an EIS emissions unit identifier. Conditional Critical
319 EIS Emissions Unit Identifier Matches Facility Site The reported EIS emissions unit identifier matches in the EIS is associated with the reported facility site. Conditional Critical
830 Agency Emissions Unit Identifier Matches Facility Site To use the agency emissions unit identifier for identification, the agency unit identifier must exist in the facility inventory for this facility site. Conditional Critical
1189 Active Identifier per Program System Code for Unit Identification Cardinality A unit may only have one active identifier for each program system code. Active means the end date is null. Currently active identifiers with matching system codes will be automatically retired. Cardinality Critical
1669 Emissions Unit Alternate Identifiers Unique The combination of emissions unit identifier and program system code must be unique within a facility site. Conditional Critical
1972 Cardinality of Active Unit Identifier in XML Only one active unit identifier per program system code per unit is allowed in an XML submission. Cardinality Critical
2368 Unit Level Agency ID Association Dependency You may not edit existing Units that do not have an identifier for your Agency. In order for you to edit this Unit, you must first have a Unit ID associated with your Agency. Conditional Critical
2373 Agency Facility Identifier Not Found when adding Unit Identifier You may not add a Unit Identifier for this Agency because no Facility Identifier for this Agency was found at the associated Facility. Conditional Critical
2374 New Unit Alternate Identifier- Agency Dependency Dependency You may not add a Unit Alternate Identifier for your Agency, because no Unit Identifier is currently reported at this Unit for your Agency. In order for you to add an Alternate Identifier for this Unit, you must first have an existing Unit ID associated with your Agency. Conditional Critical

ProgramSystemCode


Description

The code that represents the information management system which has responsibility for the data in a linked or interrelated information management system.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
168 Program System Code Present for Unit Identification A program system code is required when reporting the unit identification component. The component and all dependent data will not be stored if there are missing required data. Present Critical
234 Program System Code Valid for Unit Identification Must match value in list of registered codes. Code Critical
1189 Active Identifier per Program System Code for Unit Identification Cardinality A unit may only have one active identifier for each program system code. Active means the end date is null. Currently active identifiers with matching system codes will be automatically retired. Cardinality Critical

EffectiveDate


Description

The date on which the identifier became effective.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
169 Unit Alternate Identification Effective Date Present The unit alternate identification effective date must be reported to be accepted. Present Critical
83 Effective Date Range for Unit Identification The effective date range must be between 01/01/1900 to 12/31/2050. Range Critical
87 Effective Date and End Date Order for Unit Identification The effective date must be before the end date for an unit identification. Range Critical
272 Effective Date for Unit Identification Data Type Date in the format of YYYY-MM-DD. Format Critical

EndDate


Description

The date on which the identifier is no longer applicable.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
85 End Date Range for Unit Identification The end date must be between 01/01/1900 to 12/31/2050. Range Critical
87 Effective Date and End Date Order for Unit Identification The effective date must be before the end date for an unit identification. Range Critical
273 End Date for Unit Identification Data Type Date in the format of YYYY-MM-DD. Format Critical

IdentifierIsReadOnly


Description

Indicator preventing the value of an alternate identifier from being modified.

User Role Accessibility

Inventory Developer

Checks
Number Name Description Type Severity
1291 Identifier Protected for Unit Identification If the data in the EIS for identifier in unit identification are protected, the data will not be stored. A request to unprotect the data can be made through the Gateway. Conditional Protected
1294 Unit Alternate Identifier Protected If the data in the EIS for identifier in unit alternate identification are protected, the data will not be stored. A request to unprotect the data can be made through the Gateway. Conditional Protected Warning

UnitIdentification

User Role Accessibility
Checks
Number Name Description Type Severity
17 Emissions Unit Identifiers Present There must be an emissions unit identification component reported when reporting the emissions unit. The component and all dependent data will not be stored if there are missing required data. Present Critical
1291 Identifier Protected for Unit Identification If the data in the EIS for identifier in unit identification are protected, the data will not be stored. A request to unprotect the data can be made through the Gateway. Conditional Protected