Facility Site Control Component


The FacilitySiteControl Component contains information about the type of control being defined at the facility. Each piece of control equipment will need to be reported separately. The FacilitySiteControl component has the following attributes:

  1. The same control can be used by many different processes. This is to reduce the number of times that the control information needs to be entered.
  2. A user has the ability to define the configuration of how the controls are connected to each other at the facility. This includes the ability to model controls that are connected in a series or in parallel (the stream is split into multiple control streams).
  3. The percent emissions reduction can be calculated for a given pollutant as the emissions stream travels from the generating emissions process to the emissions release point.

The FacilitySiteControl components have the multiple sub-components defined as follows:

  1. SiteControlPollutant provides a list of pollutants the piece of control equipment is designed to control.
  2. SiteControlIdentification is the agency identifier used to track the piece of control equipment. Each agency is required to provide an identifier for the piece of control equipment.
  3. FacilitySitePath is used to define a configuration of controls used at the facility.
  4. PathDefinition - determines how the FacilitySiteControl relate to each other at the facility. The order of the controls must be specified. In cases where the emissions stream splits, the percentage of the emissions stream must be specified. This splitting of the emissions stream will cause the controls to be working in parallel until the stream meet later in the path definition. Due to the potential complicated configurations of controls, a given path definition may utilize site controls or other path definitions.
  5. ControlPathIdentification is the agency identifier used to track the given path. Each agency must provide an identifier for each path to be defined.
  6. ControlPathControlPollutant – This component captures the overall percent reductions on a per pollutant basis across the entire path. This is analogous to the existing “ControlPollutant” component that is reported with the existing “ControlApproach” component.

ControlMeasureCode


Description

Code that identifies the piece of equipment or practice that is used to reduce one or more pollutants.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
227 Control Measure Code Present Required when reporting the control measure component. The component and all dependent data will not be stored if there are missing required data. Present Critical

ControlDescription


Description

Description of the control device used at a facility.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
1033 Control Approach Description Data Type Maximum allowable width of 200 characters. Longer submissions will be truncated. Format Warning

PercentControlEffectiveness


Description

An estimate of the portion of the reporting period's activity for which the control device was operating as designed (regardless of whether the control measure is due to rule or voluntary).

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
129 Percent Effectiveness Present The percent effectiveness must be reported when reporting the site control identification component. The component and all dependent data will not be stored if there are missing required data. Present Critical
241 Percent Control Approach Effectiveness Data Type This element must be reported as a decimal, reported with a maximum precision of 5.1. Format Critical
116 Percent Control Approach Effectiveness Range Should be greater than or equal to 1, and less than or equal to 100.0. Range Critical

ControlUpgradeDate


Description

The date on which the control device was most recently updated.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
275 Upgrade Date for Site Control Identification Data Type Date in the format of YYYY-MM-DD. Format Critical
77 Upgrade Date Range The upgrade date range must be between 01/01/1900 to 12/31/2050. Range Critical

ControlUpgradeDescription


Description

Description of the control update performed for the control at a facility.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
1034 Control Upgrade Description Data Type Maximum allowable width of 200 characters. Longer submissions will be truncated. Format Warning

ControlStatusCode


Description

Code that identifies the operating status of the facility site.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
1032 Control Status Code Dependency for Site Controls A site control status may not be changed if the facility site operating status is "Temporarily Shutdown" (TS) or "Permanently Shutdown" (PS). Conditional Critical
1099 Site Control Status Code and Year If the site control status code is not "Operating" (OP), the site control status code year should be reported. Conditional Critical
1448 Site Control Status Code at Shutdown Facility A site control at a facility site with operating status of "Temporarily Shutdown" (TS) or "Permanently Shutdown" (PS) may not have a status of "Operating" (OP). Conditional Critical
184 Control Operating Status Present for Site Control Identification The control operating status is required when reporting the site control component. The component and all dependent data will not be stored if there are missing required data. Present Critical
123 Control Status Code for Site Control Valid Must match value in list of registered codes. Code Critical

ControlStatusCodeYear


Description

The year in which the operating status became applicable.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
1092 Site Control Status Code Year Data Type This element must be reported as an integer. Format Critical
1099 Site Control Status Code and Year If the site control status code is not "Operating" (OP), the site control status code year should be reported. Conditional Critical
76 Site Control Status Code Year Range The year reported should be between 1900 to 2050. Range Critical

ControlNumberOperatingMonths


Description

The number of months per year the control operates.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
245 Site Control Number of Operating Months Range The number of operating months should be between 1 and 12; inclusive. Range Critical
260 Site Control Number of Operating Months Data Type This element must be reported as an integer. Format Critical

ControlStartDate


Description

Day the control was made effective.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
140 Effective Date Range for Site Control Identification The effective date range must be between 01/01/1900 and 12/31/2050. Range Critical
141 Effective Date and End Date Order for Site Control Identification The effective date must be before the end date for a site control identification. Range Critical

ControlEndDate


Description

Day the control was no longer used.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
146 End Date Range for Site Control Identification The end date range must be between 01/01/1900 and 12/31/2050. Range Critical
145 End Date for Site Control Identification Data Type Date in the format of YYYY-MM-DD. Format Critical

ControlComment


Description

Additional information about the control.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
1035 Control Comment Data Type Maximum allowable width of 400 characters. Longer submissions will be truncated. Format Warning

ControlIsReadOnly


Description

Indicator defining that the control description information may not be altered.

User Role Accessibility

Inventory Developer

Checks
Number Name Description Type Severity
189 Site Control Protected If the data in EIS for Site Control are protected, the data will not be stored. A request to unprotect the data can be made through Gateway. Conditional Protected Warning

SiteControlIdentification Complex data type


Description

Complex data type to define identifiers by which an entity is known or has been known.

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity
2415 Agency Facility Identifier Not Found When Adding Site Control Identifier You may not add a Site Control Identifier because no Facility Identifier for this Agency was found at the associated Facility. Conditional Critical
2416 Site Control Level Agency ID Association Dependency You may not edit existing Site Controls that do not have an identifier for your Agency. In order for you to edit this Site Control, this control must have an alternate control identifier associated with your Agency. Conditional Critical
2418 New Site Control Alternate Identifier - Agency Dependency You may not add a Site Control Alternate Identifier for your Agency, because no Site Control Identifier is currently reported at this Site Control for your Agency. In order for you to add an Alternate Identifier for this Site Control, you must first have an existing Site Control ID associated with your Agency. Conditional Critical
158 Identifier Present for Site Control Alternate Identification The identifier is required when reporting the site control alternate identification component. The component and all dependent data will not be stored if there are missing required data. Present Critical

SiteControlPollutantComplex data type


Description

Complex data type to provide information on the pollutants being controlled by a collection of control devices

User Role Accessibility

SLT, Inventory Developer

Checks
Number Name Description Type Severity